Loading...
2 results
Search Results
Now showing 1 - 2 of 2
- Determination of phthalic acid esters and di(2-ethylhexyl) adipate in fish and squid using the ammonium formate version of the QuEChERS method combined with gas chromatography mass spectrometryPublication . Sambolino, Annalisa; Ortega-Zamora, Cecilia; González-Sálamo, Javier; Dinis, Ana; Cordeiro, Nereida; Canning-Clode, João; Hernández-Borges, JavierIn the present study, the ammonium formate version of the QuEChERS method, considered highly advantageous in relation to instrument maintenance and other issues, was applied for the first time to extract a group of twelve phthalic acid esters (PAEs, i.e. dipropyl phthalate, DPP; diisobutyl phthalate, DIBP; dibutyl phthalate, DBP; diisopentyl phthalate, DIPP; di-n-pentyl phthalate, DNPP; dihexyl phthalate, DHP; butyl benzyl phthalate, BBP; dicyclohexyl phthalate, DCHP; di(2-ethylhexyl) phthalate, DEHP; di-n-octyl phthalate, DNOP; diisononyl phthalate, DINP; and diisodecyl phthalate, DIDP) and one adipate (di(2-ethylhexyl) adipate, DEHA) from two species of fish (Scomber colias and Katsuwonus pelamis) and one of squid (Loligo gahi). The method was validated in terms of linearity, trueness and matrix effects. Determination coefficients (R2 ) for matrix-matched calibration curves were higher than 0.99 in all cases, being the lowest calibration levels in the range 0.5–10 ng/g. Mean recovery values were between 70 and 117% with relative standard deviation values ≤20%. Matrix effects were soft (between − 20 and +20%) for most analytes and matrices, except in squid samples, which was mostly medium with a moderate ion suppression. The analysis of 10 samples of each type showed the presence of DIBP, DBP and DEHP at concentrations up to 44.2 ± 2.1 ng/g of wet weight in some of the samples and species, still not representing concerning values when considering the daily intake of such species of seafood in the human diet (tolerable daily intake -TDI- values were not exceeded). Results demonstrated that the ammonium formate version of the QuEChERS method can be applied with success for the extraction and determination of the selected PAEs and DEHA in fish and squid samples.
- Optimization and validation of a micro–QuEChERS method for phthalates detection in small samples of cetacean blubberPublication . Sambolino, Annalisa; Rodriguez, Marta; De la Fuente, Jesus; Arbelo, Manuel; Fernández, Antonio; Kaufmann, Manfred; Cordeiro, Nereida; Dinis, AnaIn this study, an innovative method was developed to detect and quantify phthalates in fresh cetacean blubber. An adaptation of the ammonium formate QuEChERS method was used and adapted as a micro-extraction for small quantities of samples. Significantly, this technique utilized minimal quantities of reagents and salts, with the additional implementation of rigorous Quality Assurance/Quality Control protocols to further reduce background contamination. To ensure the reliability of this method, comprehensive validation procedures were conducted, with a specific focus on two widely studied cetacean species: the common bottlenose dolphin (Tursiops truncatus) and the short-finned pilot whale (Globicephala macrorhynchus). Determination coefficients (R2) for matrix-matched calibration were >0.93 with limits of quantifications (LOQ) of the method in the range of 5–10 ng/g. Mean recovery values were between 40 and 100 %. This novel methodology holds particular relevance for environmental research studies, offering the capability to detect emerging contaminants with minimal sample requirements. This aspect is particularly valuable in investigations that involve free-ranging animals and rely on biopsy sampling. It allows for the assessment of contaminant levels in healthy individuals within wild populations, enhancing our understanding of ecological impacts and potential conservation measures. • A micro-extraction adaptation of the ammonium formate QuEChERS method was developed and applied to a small quantity of fresh cetacean blubber to detect phthalates. • Small quantities of reagents and salts were used, and additional Quality Assurance/ Quality Control procedures were taken to further minimize background contamination. • Method validation was carried out for two cosmopolitan and extensively studied cetacean species: the common bottlenose dolphin (Tursiops truncatus) and the short-finned pilot whale (Globicephala macrorhynchus).