The effect of bond-slip in the assessment of reinforced concrete structures under static or dynamic cyclic loads with numerical
models may be significant. Its relevance is discussed in this paper, by analysis of the correlation of experimental and analytical
results. The latter were obtained with a perfect bond-based model and with a fiber-section beam-column model which makes
it possible to consider the effect of bond-slip in the vicinity of exterior as well of interior joints of reinforced concrete frame
structures. The experimental results consist of a shaking table test of a reinforced concrete frame, with predominant flexural
condition, in agreement with the premisses of this research. The model with bond-slip was capable of predicting the structural
behaviour in a very satisfactory manner. Furthermore, the results of the assessment including bond-slip are significantly more
accurate than those assuming perfect bond.
Description
Keywords
Reinforced concrete Bond-slip Fiber-section model Nonlinear dynamic analysis Seismic assessment . Faculdade de Ciências Exatas e da Engenharia
Citation
Lobo, P. S., Almeida, J., & Guerreiro, L. (2015). Bond-slip effect in the assessment of RC structures subjected to seismic actions. Procedia Engineering, 114, 792-799.